Compatibility
8 beta/preview
Package applicability is under review; follow the stated version and platform limits.
Download Complete inline MQS microstrip inputs (ZIP)Includes strip.ixi, process.ldf, strip.cir, README.txt. Exact checked input files plus instructions; final-release/platform applicability remains pending.

Recognise the retained result

This is a reproduced observation on a frozen Windows Studio source candidate, not a claim about every released package. After a completed 100 µm strip run, changing strip_length to 120 in Raw IXI, using Undo/Redo and saving left the earlier Results status reading Completed.

That label alone does not prove that the current source has been calculated. KB-GUI-008 tracks how the last-run result and edited source should be distinguished. The full GUI article and final-package behavior remain unqualified.

Actual saved Raw IXI source shows strip_length set to 120, alongside the same process and netlist references.
Actual saved source contains strip_length = 120 before the next extraction. Open full-size screenshot
The actual Results status row still reads Completed after saving a changed strip length, before Run again; this is the retained earlier result.
At that point the actual Results status row still read Completed for the retained earlier calculation. This is an open provenance observation, not a passed stale-state check. Open full-size screenshot

Steps

  1. Save all intended inputs. Confirm the active IXI and its process, circuit and variable values; keep a record of the input revision with the result.
  2. Use Check and run / Run full extraction. After a previous completion Basic labels the production action Run again rather than Run extraction.
  3. Wait for the new task verdict. Open Results > Raw output and check the quantities and units for that run, along with any errors or warnings.
  4. If the run fails or is cancelled, correct the cause or finish the intended edits and run again. Do not accept an old file, the earlier Completed label or an isolated numeric row as a new successful result.

Check the result

For the complete teaching example, the original 100 µm strip gives 3.89648e-12 H at GUI printed precision. Run again after saving 120 µm gives 4.67906e-12 H, matching the independently checked CLI at the same printed precision. Reverting the original input values and rerunning recovers the baseline.

The 3.9 pH design target was deliberately left unchanged during this length demonstration. Its resulting design deviation does not measure solver accuracy. Review the design target and mesh convergence separately for the actual problem.

After saving length 120 and using Run again, current native raw output gives L1 as 4.67906e-12 H. The unchanged design target is still 3.9e-12 H.
The new native run uses the saved 120 µm input and produces the larger L1. This is the result to compare with that edited input. Open full-size screenshot

Cancellation and restart

The recorded Stop action reached Cancelled while its raw output still contained an L1 row. The verdict remains Cancelled; that receipt is not accepted as a completed solve. Normal retry completed successfully.

A separate process restored the corrected saved source with the single-tab workaround, but Results was initially empty. Retained solver files did not establish a new completion. Deliberately rerunning produced the baseline. KB-GUI-006 remains separate from this after-edit finding.

If the problem remains

Read the specific current error, verify saved paths and input revision, and use the linked missing-input, licensing or port guide as appropriate. If reporting the provenance issue, include the exact application/source version, actions and a minimal public reproducer; review any logs for private design or licence information before sharing.

Sources and verification details

Recorded inputs/builds only. Complete walkthrough and final-package acceptance remain separate.

VAL-023 · Frozen Windows Studio source candidate with normal Core 8.0.1 dispatch, 3 November 2026; not a final distributed package
Normal production source edits/Undo/Redo/Save, licensed baseline/length/unit runs, port failure and correction, Stop/retry and a separate-process single-tab restart/rerun. File/directory selection used predetermined paths at the production dialog boundary
Eighteen independent checks cover these stated routes. The prior Completed label after a saved source edit remains KB-GUI-008; stale-state acceptance is not passed. A Cancelled receipt retained an L1 row and is not accepted as a completed solve. Physical pickers, complete GUI article, final distributed package, other platforms, physical accuracy and mesh convergence remain pending. KB-GUI-006 single-tab restart workaround remains separate.

studio-saved-length120
Frozen Windows Studio source candidate, actual native workflow, 3 November 2026
This image shows the stated recorded control/result only. The retained Completed-after-edit observation remains open; a Cancelled receipt is not accepted numerical success. Complete GUI article and final-package checks remain pending.

studio-prior-completed-after-edit
Frozen Windows Studio source candidate, actual native workflow, 3 November 2026
This image shows the stated recorded control/result only. The retained Completed-after-edit observation remains open; a Cancelled receipt is not accepted numerical success. Complete GUI article and final-package checks remain pending.

studio-inline-longer-inductance
Frozen Windows Studio source candidate, actual native workflow, 3 November 2026
This image shows the stated recorded control/result only. The retained Completed-after-edit observation remains open; a Cancelled receipt is not accepted numerical success. Complete GUI article and final-package checks remain pending.

  • inductex:docs/manual/studio_projects.tex · Raw IXI, saving, running and source/state identity
  • inductex:docs/manual/studio_results.tex · Results, raw output, current and retained artifacts
  • validation:studio-inputs-native-windows-20261103 · VAL-023; exact source edit/Undo/Redo/Save, retained completion observation and successful new run; KB-GUI-008 remains open
  • VAL-023 records eighteen independently checked native actions/outcomes with original teaching input bytes restored. The actual prior Completed label after saving a source edit remains KB-GUI-008; no product correction is claimed.
  • Initial capture-size and changed-button-caption helper assumptions were corrected and retained separately. They are not evidence that the product lacked a Run action.
  • Eighteen independent checks cover these stated routes. The prior Completed label after a saved source edit remains KB-GUI-008; stale-state acceptance is not passed. A Cancelled receipt retained an L1 row and is not accepted as a completed solve. Physical pickers, complete GUI article, final distributed package, other platforms, physical accuracy and mesh convergence remain pending. KB-GUI-006 single-tab restart workaround remains separate.
Read MarkdownRead structured articleBrowse all guides