8 beta/preview
Package applicability is under review; follow the stated version and platform limits.
Check the project location
- Confirm where the IXI project is saved. Read the missing-file indication on Input files.
- Check the referenced filename and its path relative to that saved project.
- If you copied only the IXI file, return to the example and copy its complete directory, including the process file, layout and netlist where that example uses them.
- Use Help > Examples / Templates > Copy to Folder when available. Save the working project and repeat Check and run.


Correct a saved process reference
- For the supplied microstrip example, keep process.ldf beside microstrip.ixi. If the saved project names a nonexistent missing-process.ldf, open Raw IXI and correct only that filename to process.ldf.
- Save the IXI, return to Basic > Check and run and wait for the file checks to finish. Run extraction should become available after the dependency is resolved.
- Run extraction and inspect the new Results/Raw output. The checked candidate completed this recovery with zero reported warnings and parsed errors, matching the original run. Use the actual filename required by your own project.
Check the result
The missing-file issue should be resolved before extraction. A successful file check establishes that the references can be read; inspect the process, geometry and electrical definitions as well before trusting a calculation.
If the problem remains
Provide the exact diagnostic and a generalised example of the relative reference. Review any support bundle before sharing it; a project may contain confidential process or design data.
Sources and verification details
Recorded inputs/builds only. Complete walkthrough and final-package acceptance remain separate.
VAL-005 · InductEx® 8.0.1 Windows catalog payload
CLI missing-process rejection
This CLI check did not exercise GUI controls. Later scoped native candidate evidence is recorded separately as VAL-015; complete GUI and final-package checks remain pending.
VAL-015 · InductEx® current-source Windows Studio candidate with Core 8.0.1; scenario executable is unversioned
Production GUI controls and normal licensed engine dispatch; current raw result, missing-process correction, GDS PNG export and separate-process restart using a single-tab workaround
Bounded native scenario on a frozen source candidate. OS picker input, a clean numerical-results screenshot, mesh refinement, cancellation and final-package acceptance remain unverified. Multi-tab exit selection is held by KB-GUI-006. Computer Use capture remains unresolved.
studio-missing-process
Windows Studio current-source native scenario, 3 November 2026
Illustrates the recorded candidate state. Full GUI article acceptance, numerical refinement and final distributed-package applicability remain pending.
studio-microstrip-inputs
InductEx® 8 document view, rendered 3 November 2026
Current-source UI illustration. No calculation or complete GUI walkthrough was performed; final-package applicability remains pending.
- inductex:docs/manual/studio_workspace.tex · Documentation and examples; Common problems
- inductex:docs/manual/studio_start.tex · First extraction: a microstrip
- validation:windows-cli-20261102 · VAL-005; scope and limits recorded
- capture:studio-ui-20261103T103032 · Reviewed current-source document-view images; UI-only scope
- validation:studio-native-windows-20261103 · VAL-015; current GUI result storage, real licensed extraction/recovery and bounded restart checks
- VAL-015 verifies the missing-process badge, disabled run control, saved editor correction and real licensed recovery on the frozen Windows candidate. Do not generalise this reference rule to another tool. Final-package and complete-article checks remain pending.