Download Run a static operating point or DC source sweep (ZIP)Includes op_bias.cir, dc_divider.cir, dc_descending.cir, README.txt. Exact checked input files plus instructions; final-release/platform applicability remains pending.

Choose the right analysis

.OP returns one selected static equilibrium, with node voltages, phase-node values, component currents and convergence scalars. It creates no time-domain waveform. .DC repeats static solves for one independent DC current or voltage source; every point starts from zero.

Use a matching 2.9 installation and valid licence. Keep one standalone OP or DC analysis in the deck. Do not add .TRAN, .STEP, .PRINT/.SAVE/.PLOT, .MEASURE or explicit .IC to these examples. A running junction’s average voltage, switching and hysteresis require dynamical analysis.

Save op_bias.cir

* Static subcritical Josephson equilibrium
.MODEL MOD JJ(IC=1m RN=5 R0=100 C=1p VG=2.8m)
I1 0 N DC 0.5m
L1 N J 2p
B1 J 0 MOD
.OPTION SEED=321
.OP
.END

Run and inspect the operating point

  1. Open the saved op_bias.cir source. Run > Analysis workbench can inspect or edit its OP entry; review and acknowledge any proposed source change before Apply, then save. Apply does not run the calculation.
  2. In Run settings choose a separate writable Primary native output such as op.csv. Save and preview the saved run plan, then use the normal Run action.
  3. Read the task verdict and document status. A successful .OP presents its scalar Results table and task output; the document status is Results current. The absence of a waveform plot is expected.
  4. Check scalar names and units, including P(J), I(L1) and OP.normalized_residual. A retained failure receipt or visible table is not proof of numerical success.
josim-pro-cli -P 17 -o op.csv op_bias.cir
Current native OP scalar table showing zero superconducting-node voltages, P(J) about 0.523599 radians, 0.0005 ampere branch currents and convergence values.
The actual licensed OP result: P(J) is about 0.523599 rad and each branch current is 0.0005 A. The upstream node N has a different phase because the inductor carries flux. Open full-size screenshot

Check the operating-point values

For this 0.5 mA bias and 1 mA sinusoidal junction, the selected junction phase is asin(0.5) = π/6 ≈ 0.523598776 rad. The superconducting nodes N and J have zero physical voltage, and I(I1), I(L1) and I(B1) are 0.0005 A in their declared first-to-second-terminal directions.

The report has one header and one numeric row. P(node) is phase in radians, V(node) is volts and I(component) is amperes. P(N) is not the same quantity as the junction-node P(J); the inductor contributes a phase difference.

Success requires OP.normalized_residual <= 1 under the static solver’s configured equation scales and phase-correction criterion. A small or zero reported residual is numerical convergence evidence, not physical accuracy, stability or root uniqueness. Transient timestep and integrator settings do not define this equilibrium.

Save dc_divider.cir

* Independent static points, not a transient or hysteresis curve
V1 IN 0 DC 42
R1 IN OUT 10
R2 OUT 0 30
C1 OUT 0 1p
.OPTION SEED=321
.DC V1 -2 2 1
.END

Run a DC source sweep

  1. Open the saved dc_divider.cir. In the Analysis workbench, DC selects V1 and start -2, stop 2, increment 1, in volts. The supplied source already contains this analysis; inspect or edit it instead of adding a second one.
  2. Choose a distinct native result path such as dc.csv, save/preview the complete plan and run. A nonzero increment must point toward the stop value.
  3. Inspect every point and its convergence data. The horizontal axis is Sweep(V1) in volts, not time in seconds; current plots may display mA while native CSV keeps A.
josim-pro-cli -P 17 -o dc.csv dc_divider.cir
Current native DC divider plots against Sweep(V1) in volts, including output voltage, branch currents, capacitor current and per-point convergence quantities.
The five current DC points plotted against the source voltage. V(OUT) follows 0.75 × V1, capacitor current is zero, and solver quantities remain separate from circuit quantities. Open full-size screenshot

Check the DC curve and direction

The CSV starts with Sweep(V1) (V). The checked points -2, -1, 0, 1 and 2 V produce V(OUT) values -1.5, -0.75, 0, 0.75 and 1.5 V. Capacitors are exactly open in this static solve, so I(C1) is zero. The original DC 42 source declaration is overridden by each requested sweep point without editing the input file.

Use the following descending variant to retain the reverse source order. An aligned endpoint is included; an unaligned stop does not create a shortened last interval. There are at most 4,096 points, with finite literal range values and no nested/two-source sweep in this interface.

Both CLI and native GUI results match the supplied equations. Gzip reports reopen with the same values. These simple examples do not validate measured-device behaviour, every supported static model or arbitrary circuit tolerances.

Save dc_descending.cir

* Independent static points, not a transient or hysteresis curve
V1 IN 0 DC 42
R1 IN OUT 10
R2 OUT 0 30
C1 OUT 0 1p
.OPTION SEED=321
.DC V1 2 -2 -1
.END

Recover without accepting a partial or failed result

Changing the OP current to 1.5 mA caused “No converged static operating point from the zero-start state” in the checked case. The GUI identified Run failed and retained a specific failed task; the previous report stayed intact. Reopening the valid 0.5 mA source and running to a new destination recovered the scalar result.

A DC point above the static junction’s supported equilibrium failed at the reported point index without publishing a partial curve or replacing an existing report. Correct the bias/model or choose an appropriate transient analysis; do not interpret the uncommitted prefix as a complete curve.

For a rejected range, correct the zero/wrong-direction increment and preview again. Remove streaming or unsupported report targets: OP/DC use CSV or CSV.gz, not waveform RAW/BIN/STDOUT. Keep the old report as a separate record and verify the fresh task verdict, filename and data.

Sources and verification details

Recorded inputs/builds only. Complete walkthrough and final-package acceptance remain separate.

VAL-018 · JoSIM®-Pro 2.9 frozen Windows source-candidate CLI, built 3 November 2026
Twenty-six checks of complete OP/DC and ideal RC AC inputs, scalar/source/frequency axes, gzip, independent equations, rejected requests, preservation and recovery
The example-specific numerical bounds do not establish physical-device calibration, stability, uniqueness or universal solver accuracy. Other devices, platforms and the final distributed package remain unverified.

VAL-019 · JoSIM®-Pro 2.9 frozen Windows native candidate with matching freshly built runtime
Normal licensed production Run actions for OP/DC/AC, OP failure with preserved prior report and recovery, current scalar/retained source-axis/typed complex results and reopening the newly written AC CSV
Sixteen independent checks cover these native actions. Paths were supplied to production OpenFile/SetRunOptions boundaries. Physical pickers, workbench Apply/Undo, cancellation, plot-export recovery, restart and final-package acceptance remain pending. A retained failure receipt is not numerical success; imported data is inspection, not a new solve or replay-safety proof.

josim-op-current-scalars
JoSIM®-Pro 2.9 frozen Windows candidate, licensed native result, 3 November 2026
The recorded candidate result illustrates this example. It does not establish physical accuracy, all GUI branches or final distributed-package applicability.

josim-dc-source-axis
JoSIM®-Pro 2.9 frozen Windows candidate, licensed native result, 3 November 2026
The recorded candidate result illustrates this example. It does not establish physical accuracy, all GUI branches or final distributed-package applicability.

  • josim-pro:docs/manual_source/sections/syntax.tex · Static operating point; Circuit DC sweeps
  • josim-pro:docs/manual_source/sections/gui_simulation_results.tex · Configure an analysis; Native imports and case review; Static operating points
  • validation:josim-static-ac-windows-20261103 · VAL-018/019; exact CLI/native actions, output/input integrity and independent numerical checks
  • owner:technical-review-20261102 · 2.9 public target; final distributed-package applicability still required
  • The maintained syntax and GUI references still match their reviewed hashes. Complete handwritten inputs are downloadable with their exact checked bytes.
  • VAL-018 records 26 CLI checks; VAL-019 records 16 independent native checks. Workbench editing, physical pickers, cancellation, restart, complete article and final-package acceptance remain pending.
Read MarkdownRead structured articleBrowse all guides