Compatibility
8 beta/preview
Package applicability is under review; follow the stated version and platform limits.

Check the physical model

  1. Confirm that the requested mode calculates the intended electrostatic or frequency-dependent quantity.
  2. Set each relevant isolation layer's relative permittivity from the process information rather than assuming vacuum.
  3. Review the environment above and below the model and the conductor/reference definitions.
  4. When comparing another solver, match geometry, dielectric stack, grounding and matrix convention before comparing entries.

Avoid changing unrelated calculations

A magnetoquasistatic inductance calculation and an electrostatic capacitance calculation make different physical approximations. Changing a dielectric constant is not a general fix for an MQS inductance discrepancy.

A Maxwell capacitance matrix and a circuit representation need consistent sign/reference conventions. No conversion recipe is inferred from an unresolved comparison in the support history.

Sources and verification details

Recorded inputs/builds only. Complete walkthrough and final-package acceptance remain separate.

  • support:SUP-010 · Generalised editorial finding; outcome qualification retained
  • inductex:docs/manual/ix_ldf.tex · EpsilonR; EpsilonRAbove; EpsilonRBelow
  • Support history informed this draft. Current-source guidance has been checked; a fresh walkthrough on the intended distributed release and product-owner review remain pending.