Compatibility
8 draft guidance; 6.x/7.x historical outcomes
Package applicability is under review; follow the stated version and platform limits.
8 draft guidance; 6.x/7.x historical outcomes
Package applicability is under review; follow the stated version and platform limits.
Inspect the physical contact
- Show the terminal object, its label and the target conductor together.
- Check that the terminal clearly intersects the intended conductor and does not depend on an ambiguous edge-only contact.
- Inspect the generated mesh/geometry near the terminal and read the first error.
- Check that the two terminals excite the intended distinct electrical locations. If both are connected to the same shorted object, redesign the measurement/return-path model rather than expecting a meaningful branch voltage.
Keep workarounds versioned
In one legacy case, extending a terminal across the relevant polygon edges removed a zero-length-edge failure. This is a useful geometry check, not a universal solver fix.
Return conductors, shared terminal objects, airbridges and off-chip connections have version-dependent modelling constraints. Use the matching manual and a small test model before applying a workaround to a larger design.
Sources and verification details
Recorded inputs/builds only. Complete walkthrough and final-package acceptance remain separate.
- support:SUP-007 · Generalised editorial finding; outcome qualification retained
- inductex:docs/manual/ix_ports.tex · Port and terminal definitions
- inductex:docs/manual/studio_layout.tex · Layout inspection
- Support history informed this draft. Current-source guidance has been checked; a fresh walkthrough on the intended distributed release and product-owner review remain pending.