Simulating phase slips in a shunted Josephson junction.
Follow a resistively shunted Josephson junction from its netlist and schematic to the simulated voltage and phase response. Three current triggers each produce a single phase slip in this generic classical model.
Files and software
Use a matching licensed JoSIM®-Pro 2.9 installation. The ZIP contains the circuit and a native GUI reference CSV. A separate command-line check reproduced all three single-slip events.
1. Open the circuit and inspect its parameters.
Extract the ZIP into a writable folder. Open junction-sfq.cir in JoSIM®-Pro GUI 2.9 and review Source before running the model.
Junction and drive
-
Critical current IC = 100 µA, capacitance CAP = 100 fF and a separate 5 Ω shunt.
-
A 70 µA DC bias places the junction below its critical current.
-
Each short trigger pulse adds 80 µA to the bias.
-
The transient uses a 0.05 ps step through 240 ps.
The requested outputs are I(ITRIG), V(j) and P(B1). The parameters describe a generic classical RCSJ model and do not come from a foundry PDK.
2. Compare the schematic with the source.
Open Schematic for the same circuit. Identify the bias source, trigger source, junction and external shunt, then compare their connections with the netlist.
If a component value or model needs attention, return to Source to review it. Keep the original download unchanged and use a separate copy when experimenting.
The schematic represents the circuit definition. The simulation results are examined in the next step.
3. Relate the voltage pulses to the phase response.
Run the simulation, open Results and inspect the trigger current, junction voltage and junction phase together. The reference run contains 4,801 samples over 240 ps, with triggers at 60, 120 and 180 ps. Initial bias settling occurs before the first trigger.
Interpreting a switching event
After each event has settled, the phase has advanced by 2π and the voltage pulse integrates to one flux quantum. These two observations are connected by the Josephson voltage relation:
V = (Φ₀ / 2π) dφ/dt
The result illustrates a classical shunted-junction model. It does not represent a measured device, a qubit state or foundry qualification.
4. Compare a new run with the reference.
Keep native-results.csv unchanged and export any new results to a different file so the supplied reference remains available for comparison.
Command-line route
josim-pro-cli -o new-results.csv junction-sfq.cir
Comparing the files
Time, current and voltage use SI units; phase is expressed in radians. Preserve the native header quoting when importing a result file. The separate 2.9 CLI check produced 4,801 finite samples and one phase turn per trigger, although text precision differs between the CLI and GUI exports.
If a result is missing
If Run is unavailable, check the 2.9 installation, licence and daemon. If traces are missing, check the .PRINT line and the current Results selection.