Compatibility
2.9.0 release target; review-build/source evidence
Package applicability is under review; follow the stated version and platform limits.

Check the exact restriction

The maintained manual documents variable-step support for PHASE analysis with BDF integration. LOSSLESS transmission lines block this mode; an untyped T element defaults to LOSSLESS.

Choose a valid run

  1. Read the diagnostic's list of blocking lines and check the model assigned to each.
  2. Use a validated fixed-step setup for LOSSLESS lines.
  3. Use LCLADDER only when its finite LC-ladder approximation is physically appropriate. Do not change the model merely to silence the restriction.
  4. Repeat the calculation with a smaller nominal step when validating edges or amplitudes; accepted settings alone do not establish convergence.
Sources and verification details

Recorded inputs/builds only. Complete walkthrough and final-package acceptance remain separate.

  • support:SUP-016 · Generalised editorial finding; outcome qualification retained
  • josim-pro:docs/manual_source/sections/troubleshooting.tex · Variable-step mode or runtime options are incompatible with the netlist
  • owner:technical-review-20261102 · JoSIM®-Pro 2.9 chosen as the public starting path; release availability must be checked before publication
  • Support history informed this draft. Current-source guidance has been checked; a fresh walkthrough on the intended distributed release and product-owner review remain pending.