2.9.0 release target; frozen Windows candidate CLI and maintained-source evidence
Package applicability is under review; follow the stated version and platform limits.
Build and review a sweep in the GUI
The supplied bias_sweep.cir already contains both sweep dimensions. Inspect or edit those entries rather than adding duplicate dimensions. For a new circuit, create the bias LIST values 1m 2m and the resistance range 3 to 1 with increment -1; suffixes retain their electrical meaning.
- Open a complete editable netlist with the required global .PARAM declarations and an explicit .TRAN or .IV analysis.
- Open Run > Sweep and measurement workbench. Select Parameter sweep, the source scope and declared parameter. Choose LIST values or a linear range.
- Use template to replace the proposed command. Editing a template field alone does not replace source. Preview changes, inspect the complete diff, acknowledge the review and apply it.
- Add a second dimension in the same scope for a Cartesian sweep. Save, then use Preview saved run plan to verify actual assignments, case order, effective seeds and destinations before Run.
- After execution inspect each case’s status and committed data. Compare plots only for successful retained cases with identical stored time coordinates; use tables or separate files when grids differ.

Save the complete example as bias_sweep.cir
* Six independent bias/resistance cases; last dimension varies fastest
.PARAM bias=1m
.PARAM resistance=1
I1 0 N DC bias
R1 N 0 resistance
.OPTION ANALYSIS=VOLTAGE INTEGRATION=BDF SEED=27
.STEP PARAM bias LIST 1m 2m
.STEP PARAM resistance 3 1 -1
.TRAN 1p 5p
.PRINT V(N)
.MEASURE TRAN output_peak MAX V(N)
.END
Run the example from the CLI
Use one .PARAM assignment per line. Sweep values must be finite numeric constants; the default parameter declarations must also resolve. A linear increment must be nonzero and point toward the stop value.
Multiple dimensions form a Cartesian product and the last varies fastest. This example uses bias 1 mA then 2 mA; each bias visits resistance 3, 2 and 1 ohm. Each case is a fresh simulation, with no continuation history.
josim-pro-cli -P 17 -o sweep.csv bias_sweep.cirCheck all six cases
The checked output names run from sweep.tran-001.case-1.csv to sweep.tran-006.case-6.csv. The unsuffixed sweep.csv is not written. Use the actual planned/reported job ID rather than guessing a filename.
Each file has six rows over 0–5 ps and V(N) in volts. In source order the constant values are 0.003, 0.002, 0.001, 0.006, 0.004 and 0.002 V, matching I × R for this simple circuit. The independent check used relative 1e-12 and absolute 1e-15 V comparison bounds for this example only.
There are at most eight dimensions, 256 values per dimension and 256 total jobs per deck, including unswept analyses. These are run-count limits, not guarantees about memory or duration. Serial execution is the default; parallel eligibility is a separate platform-specific contract.
Recover from a rejected sweep
- Read the source-located .STEP diagnostic. Check declared parameter names, finite literal values, duplicate dimensions, increment direction and expanded case count.
- For the descending resistance range in this example, restore increment -1 if it was changed to zero. The checked zero-increment request failed before replacing a pre-existing output; the corrected six-case example completed.
- Keep each earlier committed result with its case identity after a failure. A failed or not-run case is not a successful simulation.
Sources and verification details
Recorded inputs/builds only. Complete walkthrough and final-package acceptance remain separate.
VAL-017 · JoSIM®-Pro 2.9 frozen Windows source candidate built 3 November 2026; not the final distributed package
Fixed-seed noise/spread repetition and CLI precedence; buffered/streamed/gzip data; six Cartesian sweep cases; saved testbench verdicts, provenance hashes, generation protection and recovery
Twenty-two checks cover these CLI inputs and runtime only. Native screenshots illustrate authoring/settings controls without a GUI calculation, preview or saved-bench run. Cross-platform repeatability, peak memory, cancellation, other analysis families and final-package acceptance remain unverified. The constant-circuit numerical bounds are example-specific, not universal solver tolerances.
josim-sweep-workbench
JoSIM®-Pro 2.9 frozen Windows candidate, native controls, 3 November 2026
A native control illustration. The separately recorded CLI examples do not qualify this GUI route or the final distributed package.
- josim-pro:docs/manual_source/sections/syntax.tex · Parameter sweeps; Parameter definition
- josim-pro:docs/manual_source/sections/gui_simulation_results.tex · Sweeps, named groups and measurements
- validation:josim-jobs-windows-20261103 · VAL-017; exact complete inputs, checked CLI outcomes and limits
- capture:josim-jobs-ui-20261103T145751 · Production control illustrations only; no GUI solve, preview or bench run
- owner:technical-review-20261102 · 2.9 public target; final distributed-package checks required
- VAL-017 checks the supplied CLI recipe on the frozen Windows candidate. The source manuals still match their reviewed hashes.
- Native images illustrate actual controls; the settings/workbench were cancelled and the testbench view hidden. Complete GUI, technical and final-package acceptance remain pending.