2.9.0 release target; review-build/source evidence
Package applicability is under review; follow the stated version and platform limits.
Thermal-noise settings
The maintained syntax uses .TEMP for temperature in kelvin and .NEB for effective noise bandwidth in hertz. Supported devices may override the global settings with temp= and neb=.
Enter a temperature such as 77 kelvin as .TEMP 77. Do not append the engineering suffix K expecting a kelvin unit: in numeric expressions it can mean a factor of one thousand.
.TEMP 4.2
.NEB 1GHz
R1 1 0 50 temp=4.2 neb=1GHzExplicit noise waveform
NOISE(A [Td [Ts]]) takes a spectral amplitude, start delay and sample time; the documented default sample time is Tstep. This is a separate interface from .TEMP/.NEB.
Keep simulation timestep, noise sampling and measurement/averaging windows explicit when comparing runs. Account for random realisations and settling; a different trace is not alone evidence of changed noise power.
Avoid a universal conversion formula
Historical correspondence corrected earlier bandwidth/sample-time advice. This draft intentionally does not supply one conversion between effective thermal bandwidth and an arbitrary explicit sampled-noise source. Verify the intended noise definition and current implementation before quantitative comparisons.
Junction model T/TC parameters can also change device behaviour; that is separate from adding thermal-noise excitation.
Sources and verification details
Recorded inputs/builds only. Complete walkthrough and final-package acceptance remain separate.
- support:SUP-014 · Generalised editorial finding; outcome qualification retained
- support:SUP-015 · Generalised editorial finding; outcome qualification retained
- josim-pro:docs/manual_source/sections/syntax.tex · Noise; noise settings; Josephson junction parameters
- owner:technical-review-20261102 · JoSIM®-Pro 2.9 chosen as the public starting path; release availability must be checked before publication
- Temperature suffix and quantitative noise behaviour still need a fresh controlled walkthrough. Historical formula corrections are not numerical validation of this draft.
- The owner accepted the modelling explanation on 2 November 2026. Applicable release/platform and unrecorded walkthrough checks remain pending.