{"sections":[{"heading":"Before starting","paragraphs":["Use an InductEx 8 installation with Studio and a valid extraction licence. Install the SUN Magnetics licence daemon required by that release. Opening a file for inspection does not prove that extraction is licensed."]},{"figures":[{"asset_id":"studio-microstrip-inputs","caption":"Keep the three supplied input files together and check that each reference is available."},{"asset_id":"studio-mqs-electrical","caption":"Keep the circuit netlist selected for mapped inductance/resistance results; netlist-free inspection has a different purpose."}],"heading":"Open and check the example","steps":["In Help > Examples / Templates, select the microstrip inductance example and choose Copy to Folder. Alternatively, copy the complete examples/inductance/microstrip directory to a writable location.","Use File > Open Folder to open that working directory, then open microstrip.ixi.","On Basic, check that Extraction goal is MQS. In Input files, check process.ldf, microstrip.cir and microstrip.gds. Keep the supplied electrical setup and port declarations for this first run."]},{"figures":[{"asset_id":"studio-microstrip-review","caption":"Review readiness and the reported issues before choosing Run extraction. This image illustrates the controls rather than a completed run."}],"heading":"Check and run","steps":["Open Review, then Check and run. Resolve reported input problems and save the project.","Choose Run extraction or Run > Run full extraction. Wait for completion and read the messages in the output panel."]},{"heading":"Check the result","paragraphs":["Open Results and read the current status, warning/error counts and Raw output. Check the quantities and units before accepting the calculation. A completion message alone is insufficient.","The recorded licensed Windows Studio candidate produced L1 = 3.89648 pH against a 3.9 pH design, approximately 0.0903% deviation. The missing-process correction reproduced that value, which also matches the earlier CLI observation at the recorded precision.","This GUI route keeps the numerical summary in memory. It produced solver_out.txt and other solver artifacts but no sol.txt. Use the current Results/Raw output; a CLI solution file left by another run does not establish the GUI outcome.","These fixed-input checks do not establish mesh convergence or general numerical accuracy. Full article acceptance, an appropriate numerical-results image and final-package checks remain pending."]},{"heading":"Compare with the design","paragraphs":["Aim for low reported relative error in the model fit. The owner has not specified a new numerical cutoff for SVD or GMRES residuals.","For a meaningful nonzero design inductance, use 100 × abs(L_extracted − L_design) / abs(L_design) to compare the values. The general design target is below 10% deviation; below 5% is preferred.","Design agreement, model-fit residuals and solver convergence answer different questions. Check the physical model and refinement behaviour as well; these percentages are not universal solver-error or regression tolerances."]},{"figures":[{"asset_id":"studio-microstrip-layout-export","caption":"The PNG written by the production GDS snapshot action for this working copy; software rendering was used."}],"heading":"Save a layout image","steps":["Open microstrip.gds, then choose File > Export Snapshot and save a PNG to a new destination.","Open the saved PNG and confirm it contains the intended layout. Keep its generated report with the calculation record. A geometry image does not establish mesh or extraction accuracy."]},{"heading":"Close and reopen the project","paragraphs":["Save any edits before exiting. In the checked Windows source candidate, exiting with several tabs restored the last tab rather than the selected one. Until that issue is resolved for the release, close other saved tabs before exiting if you need this project restored as active.","After reopening, verify the project name and Basic step. The checked single-tab path restored Check and run. Its Results summary was empty in the new process even though solver files remained on disk. Run again for a new GUI result; retain the earlier output as a separate calculation record."]}],"canonical_url":"https://www.sun-magnetics.com/knowledge-base/inductex-first-microstrip","url":"/knowledge-base/inductex-first-microstrip","known_issues":[{"disposition":"verified_workaround","id":"KB-GUI-006","title":"Normal multi-tab exit saves the last tab as active","public_notice":"Save work and close other saved tabs before exit when the intended Studio project must return as active. The checked single-tab restart does not repair multi-tab selection.","claim_scope":"Only the affected claim and recorded build/input; not whole-guide or final-release acceptance"}],"search_record":{"execution":true,"relatedProducts":[],"version_tags":["InductEx 8 preview"],"text":"Run your first microstrip extraction in Studio Copy the complete microstrip example to a writable folder, open microstrip.ixi, check its inputs and run the extraction from Studio. InductEx 8 beta/preview Get started first run getting started microstrip run extraction Before starting Use an InductEx 8 installation with Studio and a valid extraction licence. Install the SUN Magnetics licence daemon required by that release. Opening a file for inspection does not prove that extraction is licensed.  Open and check the example In Help > Examples / Templates, select the microstrip inductance example and choose Copy to Folder. Alternatively, copy the complete examples/inductance/microstrip directory to a writable location. Use File > Open Folder to open that working directory, then open microstrip.ixi. On Basic, check that Extraction goal is MQS. In Input files, check process.ldf, microstrip.cir and microstrip.gds. Keep the supplied electrical setup and port declarations for this first run.  Keep the three supplied input files together and check that each reference is available. Studio Input files showing microstrip.gds, process.ldf and microstrip.cir as available. Keep the circuit netlist selected for mapped inductance/resistance results; netlist-free inspection has a different purpose. Studio MQS electrical setup with microstrip.cir selected and netlist-free current or field inspection unchecked. Check and run Open Review, then Check and run. Resolve reported input problems and save the project. Choose Run extraction or Run > Run full extraction. Wait for completion and read the messages in the output panel.  Review readiness and the reported issues before choosing Run extraction. This image illustrates the controls rather than a completed run. Studio Check and run with readiness information, Review issues and Run extraction controls. Check the result Open Results and read the current status, warning/error counts and Raw output. Check the quantities and units before accepting the calculation. A completion message alone is insufficient. The recorded licensed Windows Studio candidate produced L1 = 3.89648 pH against a 3.9 pH design, approximately 0.0903% deviation. The missing-process correction reproduced that value, which also matches the earlier CLI observation at the recorded precision. This GUI route keeps the numerical summary in memory. It produced solver_out.txt and other solver artifacts but no sol.txt. Use the current Results/Raw output; a CLI solution file left by another run does not establish the GUI outcome. These fixed-input checks do not establish mesh convergence or general numerical accuracy. Full article acceptance, an appropriate numerical-results image and final-package checks remain pending.  Compare with the design Aim for low reported relative error in the model fit. The owner has not specified a new numerical cutoff for SVD or GMRES residuals. For a meaningful nonzero design inductance, use 100 × abs(L_extracted − L_design) / abs(L_design) to compare the values. The general design target is below 10% deviation; below 5% is preferred. Design agreement, model-fit residuals and solver convergence answer different questions. Check the physical model and refinement behaviour as well; these percentages are not universal solver-error or regression tolerances.  Save a layout image Open microstrip.gds, then choose File > Export Snapshot and save a PNG to a new destination. Open the saved PNG and confirm it contains the intended layout. Keep its generated report with the calculation record. A geometry image does not establish mesh or extraction accuracy.  The PNG written by the production GDS snapshot action for this working copy; software rendering was used. A native GDS snapshot export of the supplied straight microstrip layout on a grid. Close and reopen the project Save any edits before exiting. In the checked Windows source candidate, exiting with several tabs restored the last tab rather than the selected one. Until that issue is resolved for the release, close other saved tabs before exiting if you need this project restored as active. After reopening, verify the project name and Basic step. The checked single-tab path restored Check and run. Its Results summary was empty in the new process even though solver files remained on disk. Run again for a new GUI result; retain the earlier output as a separate calculation record. ","id":"inductex-first-microstrip","keywords":"first run getting started microstrip run extraction","kind":"Get started","title":"Run your first microstrip extraction in Studio","product":"InductEx"},"version":"8 beta/preview","id":"inductex-first-microstrip","related":["/knowledge-base/inductex-run-unavailable","/knowledge-base/inductex-missing-input","/knowledge-base/inductex-restart-state"],"downloads":[],"publication_status":"published","numerical_output":null,"provenance":{"execution_checks":[{"scope":"CLI extraction only","result":"passed","articles":["inductex-first-microstrip"],"version":"InductEx 8.0.1 Windows catalog payload","id":"VAL-001","records":["catalog-microstrip"],"limit":"Single fixed-input run; no accuracy or convergence qualification. GUI workflow pending.","observed":{"L1_henry":3.89648e-12,"L1_picohenry":3.8964800000000004}},{"routes":["gui-native-scenario"],"scope":"Production GUI controls and normal licensed engine dispatch; current raw result, missing-process correction, GDS PNG export and separate-process restart using a single-tab workaround","result":"passed","articles":["inductex-first-microstrip","inductex-missing-input","inductex-read-results"],"purpose":"studio-microstrip-native-run-recovery-restart","version":"InductEx current-source Windows Studio candidate with Core 8.0.1; scenario executable is unversioned","id":"VAL-015","records":["studio-native-run","studio-native-restart","independent-review"],"limit":"Bounded native scenario on a frozen source candidate. OS picker input, a clean numerical-results screenshot, mesh refinement, cancellation and final-package acceptance remain unverified. Multi-tab exit selection is held by KB-GUI-006. Computer Use capture remains unresolved.","observed":{"microstrip":{"design_H":3.9e-12,"design_deviation_percent":0.0902564102563991,"extracted_H":3.89648e-12},"recovery":{"design_H":3.9e-12,"design_deviation_percent":0.0902564102563991,"extracted_H":3.89648e-12}}}],"figure_evidence":[{"evidence_limit":"Current-source UI illustration. No calculation or complete GUI walkthrough was performed; final-package applicability remains pending.","id":"studio-microstrip-inputs","reference_label":"InductEx 8 document view, rendered 3 November 2026"},{"evidence_limit":"Current-source UI illustration. No calculation or complete GUI walkthrough was performed; final-package applicability remains pending.","id":"studio-mqs-electrical","reference_label":"InductEx 8 document view, rendered 3 November 2026"},{"evidence_limit":"Current-source UI illustration. No calculation or complete GUI walkthrough was performed; final-package applicability remains pending.","id":"studio-microstrip-review","reference_label":"InductEx 8 document view, rendered 3 November 2026"},{"evidence_limit":"Illustrates the recorded candidate state. Full GUI article acceptance, numerical refinement and final distributed-package applicability remain pending.","id":"studio-microstrip-layout-export","reference_label":"Windows Studio current-source native scenario, 3 November 2026"}],"review_notes":["VAL-015 verifies scoped native controls, real licensed dispatch, output, recovery and a separate-process single-tab restart. Multi-tab exit remains KB-GUI-006. Numerical refinement, useful result imagery and the final distributed package remain pending."],"scope":"Recorded inputs/builds only. Complete walkthrough and final-package acceptance remain separate.","verification_requirements":{"gui_method":"product-native scenario or recorded operator walkthrough; screenshots required for GUI guidance","status":"review-incomplete","illustrations":"required","required":["technical-review","release-applicability","gui-workflow","execution","numerical-interpretation","illustrations"],"legacy_walkthrough_field":"pending retained; not evidence of a complete scenario"},"sources":[{"id":"inductex:docs/manual/studio_start.tex","section":"First extraction: a microstrip"},{"id":"validation:windows-cli-20261102","section":"VAL-001; scope and limits recorded"},{"id":"owner:technical-review-20261102","section":"Owner guidance on low relative error and design-inductance agreement"},{"id":"validation:design-comparison-20261102","section":"VAL-001 arithmetic assessment against the design value"},{"id":"capture:studio-ui-20261103T103032","section":"Reviewed current-source document-view images; UI-only scope"},{"id":"validation:studio-native-windows-20261103","section":"VAL-015; current GUI result storage, real licensed extraction/recovery and bounded restart checks"}]},"title":"Run your first microstrip extraction in Studio","type":"Get started","markdown_url":"/_functions/kbResource?path=markdown%2Finductex-first-microstrip.md","summary":"Copy the complete microstrip example to a writable folder, open microstrip.ixi, check its inputs and run the extraction from Studio.","product":"InductEx"}